NP5 EtherCAT Online Manual

3321h Analogue Input Offset

Function

Offset that is added to the read analog value (3320h) before dividing by the divisor from object 3322h.

Object description

Index 3321h
Object name Analogue Input Offset
Object Code ARRAY
Data type INTEGER32
Savable yes, category: application
Firmware version FIR-v1426
Change history

Value description

Subindex 00h
Name Number Of Analogue Inputs
Data type UNSIGNED8
Access read only
PDO mapping no
Allowed values
Preset value 02h
Subindex 01h
Name Analogue Input 1
Data type INTEGER32
Access read / write
PDO mapping no
Allowed values
Preset value 00000000h
Subindex 02h
Name Analogue Input 2
Data type INTEGER32
Access read / write
PDO mapping no
Allowed values
Preset value 00000000h

Description

  • Subindex 00h: Number of offsets
  • Subindex 01h: Offset for analog input 1
  • Subindex 02h: Offset for analog input 2
▶   next

Contents



Privacy settings
We use cookies to personalise content and ads, to provide social media features and to analyse our traffic. We also share information about your use of our site with our social media, advertising and analytics partners who may combine it with other information that you’ve provided to them or that they’ve collected from your use of their services. Use necessary cookies only.