C5 USB Online Manual

60E9h Additional Feed Constant - Feed

Function

In this object and in 60EEh, you can set a feed constant for each existing feedback.

Object description

Index 60E9h
Object name Additional Feed Constant - Feed
Object Code ARRAY
Data type UNSIGNED32
Savable yes, category: application
Access read only
PDO mapping RX-PDO
Allowed values
Preset value
Firmware version FIR-v1738-B501312
Change history

Value description

Subindex 00h
Name Number Of Entries
Data type UNSIGNED8
Access read only
PDO mapping RX-PDO
Allowed values
Preset value 01h
Subindex 01h
Name Additional Feed Constant - Feed Feedback Interface #1
Data type UNSIGNED32
Access read / write
PDO mapping RX-PDO
Allowed values
Preset value 00000001h

Description

The subindices have the following function:

  • 00h: Value = "n", where "n" is the number of existing feedbacks.
  • nh: Subindex "n" contains the feed in user-defined units for the corresponding feedback.

    Subindex 01h always corresponds to the first (and always existing) sensorless feedback.

The feed constant of feedback "n" is calculated as follows:

Feed Constant = Feed (60E9h:nh) / Driving Shaft Revolutions (60EEh:nh)