2034h Upper Voltage Warning Level

Function

This object contains the threshold value for the "overvoltage" error in millivolts.

Object description


Index 2034h
Object name Upper Voltage Warning Level
Object Code VARIABLE
Data type UNSIGNED32
Savable yes, category: application
Access read / write
PDO mapping no
Allowed values  
Preset value
  • PD2-C4118X1404-E-08: 0000C92Ch
  • PD2-C4118L1804-E-08: 0000C92Ch
  • PD2-CB42M024040-E-08: 00007530h
  • PD2-CB42C048040-E-08: 0000C92Ch
  • PD2-C411L18-E-65-08: 0000C92Ch
  • PD2-CB42CD-E-65-08: 0000C92Ch
Firmware version FIR-v1426
Change history  

Description

If the input voltage of the controller exceeds this threshold value, the motor is switched off and an error triggered. This error is reset automatically if the input voltage is less than (voltage of object 2034h minus 2 volts).

▶   next

Contents



Privacy settings
We use cookies to personalise content and ads, to provide social media features and to analyse our traffic. We also share information about your use of our site with our social media, advertising and analytics partners who may combine it with other information that you’ve provided to them or that they’ve collected from your use of their services. Use necessary cookies only.