NP5 EtherCAT Online Manual

3320h Read Analogue Input

Function

Displays the instantaneous values of the analog inputs in user-defined units.

Object description

Index 3320h
Object name Read Analogue Input
Object Code ARRAY
Data type INTEGER32
Savable no
Firmware version FIR-v1426
Change history

Value description

Subindex 00h
Name Number Of Analogue Inputs
Data type UNSIGNED8
Access read only
PDO mapping no
Allowed values
Preset value 02h
Subindex 01h
Name Analogue Input 1
Data type INTEGER32
Access read only
PDO mapping TX-PDO
Allowed values
Preset value 00000000h
Subindex 02h
Name Analogue Input 2
Data type INTEGER32
Access read only
PDO mapping TX-PDO
Allowed values
Preset value 00000000h

Description

The user-defined units are made up of offset (3321h) and pre-scaling value (3322h). If both object entries are still set to the default values, the value in 3320h is specified in the "ADC digits" unit.

Formula for converting from digits to the respective unit:

  • Voltage input: x digits * 3.3 V / 1024 digits
  • Current input: x digits * 20 mA / 1024 digits

The following applies for the sub-entries:

  • Subindex 00h: Number of analog inputs
  • Subindex 01h: Analog value 1
  • Subindex 02h: Analog value 2
▶   next

Contents



Privacy settings
We use cookies to personalise content and ads, to provide social media features and to analyse our traffic. We also share information about your use of our site with our social media, advertising and analytics partners who may combine it with other information that you’ve provided to them or that they’ve collected from your use of their services. Use necessary cookies only.