3221h Analogue Inputs Control
Function
With this object, an analog input can be switched from voltage measurement to current measurement.
Object description
Index | 3221h |
Object name | Analogue Inputs Control |
Object Code | VARIABLE |
Data type | INTEGER32 |
Savable | yes, category: application |
Access | read / write |
PDO mapping | no |
Allowed values | |
Preset value | 00000000h |
Firmware version | FIR-v1426 |
Change history |
Description
In general: If a bit is set to the value "0", the analog input measures the voltage; if the bit is set to the value "1", the current is measured.
- AC1
- Setting for analog input 1
- AC2
- Setting for analog input 2