CL3-E CANopen/USB Technical Manual

3322h Analogue Input Pre-scaling

Function

Value with which the read-in analog value (3320h, 3321h) is divided before it is written into object 3320h.

Object description


Index 3322h
Object Name Analogue Input Pre-scaling
Object Code ARRAY
Data type INTEGER32
Saveable yes, category: application
Firmware Version FIR-v1426
Change History  

Value description


Sub-index 00h
Name Number Of Analogue Inputs
Data type UNSIGNED8
Access Read only
PDO Mapping No
Admissible Values  
Specified Value 02h


Sub-index 01h
Name Analogue Input 1
Data type INTEGER32
Access Read/write
PDO Mapping No
Admissible Values All values allowed, except 0
Specified Value 00000001h


Sub-index 02h
Name Analogue Input 2
Data type INTEGER32
Access Read/write
PDO Mapping No
Admissible Values All values allowed, except 0
Specified Value 00000001h

Description

  • Sub-index 00h: Number of dividers
  • Sub-index 01h: Divider for analog input 1
  • Sub-index 02h: Divider for analog input 2