CL3-E CANopen/USB Technical Manual

3221h Analogue Inputs Control

Function

This object can be used to change an analog input from voltage to current measurement.

Object description


Index 3221h
Object Name Analogue Inputs Control
Object Code VARIABLE
Data type INTEGER32
Saveable yes, category: application
Access Read/write
PDO Mapping No
Admissible Values  
Specified Value 00000000h
Firmware Version FIR-v1426
Change History  

Description

In general: If a bit is set to 0, the analog input measures the voltage; if the bit is set to 1, the current is measured.

AC1
Setting for analog input 1
AC2
Setting for analog input 2
▶   next

Contents