CL3-E CANopen/USB Technical Manual

2031h Maximum Current

Function

If open-loop mode is selected and I2t monitoring is not activated, the rated current from the motor datasheet should be entered here. (in mA as root mean square (RMS)). Is closed-loop mode selected and I2t monitoring has been activated, it defines the peak current as RMS in mA.

Object description


Index 2031h
Object Name Maximum Current
Object Code VARIABLE
Data type UNSIGNED32
Saveable yes, category: tuning
Access Read/write
PDO Mapping No
Admissible Values  
Specified Value 0000012Ch
Firmware Version FIR-v1426
Change History

Firmware Version FIR-v1614: Entry "Saveable" modified from "yes, category: application" to "yes, category: tuning".

Firmware Version FIR-v1614: Entry "Object Name" modified from "Peak Current" to "Max Current".